Quality & Statistics
Gage R&R Calculator
Evaluate your measurement system — repeatability, reproducibility, %GRR, and the number of distinct categories from a crossed study.
One row per operator and trial, grouped by operator (op 1 trial 1, op 1 trial 2, …). One column per part.
Result
- Distinct categories (ndc)
- —
- %Tolerance (6σ GRR ÷ tolerance)
- —
%GRR = σ gage ÷ σ total
σ gage = √(repeatability² + reproducibility²)
Average and range method (AIAG MSA). Under 10% is acceptable, 10–30% marginal, over 30% unacceptable.
What is Gage R&R?
Gage R&R (Repeatability and Reproducibility) is a measurement system analysis that quantifies the amount of variation in your measurement process. It separates measurement variation into:
- Repeatability: same operator, same part, same gage (equipment variation)
- Reproducibility: different operators, same part, same gage (operator variation)
Acceptance criteria
| %GRR | Decision |
|---|---|
| ≤ 10% | Acceptable |
| 10% – 30% | May be acceptable depending on the application, the cost of the gage, and the cost of repair |
| > 30% | Unacceptable — improve the measurement system |
Independently of %GRR, the AIAG MSA manual asks for NDC ≥ 5; below that the gage cannot resolve enough of the process variation for control.